Anka Sci-tech Co., Limited

Do fire detectors detect carbon monoxide​

By:Anka Sci-tech Co., Limited
Date:2025-04-25
share:

When it comes to home safety systems, there's significant confusion between fire detectors, smoke alarms, and carbon monoxide (CO) detectors. Many people assume these devices are interchangeable, but this misunderstanding could have dangerous consequences.

Critical Safety Information: Standard fire detectors and smoke alarms cannot detect carbon monoxide gas. You need dedicated CO detectors or combination units to protect against this invisible threat.

Understanding the Different Detection Technologies

Device Type What It Detects Detection Method Alarm Purpose
Smoke Detector Smoke particles from fires Ionization or photoelectric sensors Fire warning
Heat Detector Rapid temperature rise Thermistor or fusible alloy Fire warning
Carbon Monoxide Detector CO gas molecules Electrochemical, biomimetic, or metal oxide semiconductor Poisoning warning

Why Fire Detectors Can't Detect CO

Fire detectors and CO detectors serve fundamentally different purposes:

  • Different threats: Fire detectors respond to physical signs of fire (smoke, heat), while CO detectors sense a specific gas
  • Different sensor technologies: The sensors in smoke detectors have no way to identify CO molecules
  • Different alarm thresholds: CO becomes dangerous at concentrations (50+ PPM) far below what would trigger smoke detection
  • Different response needs: CO poisoning requires different emergency response than a fire

Key Takeaway: A working smoke alarm can save your life in a fire, but it won't protect you from carbon monoxide poisoning. You need both types of detectors for complete home safety.

Types of Fire Detection Systems

Understanding common fire detection technologies helps clarify why they don't detect CO:

1. Ionization Smoke Alarms

  • Contain a small amount of radioactive material
  • Detect invisible combustion particles from flaming fires
  • More responsive to fast, flaming fires

2. Photoelectric Smoke Alarms

  • Use light beams to detect visible smoke particles
  • Better at detecting smoldering, smoky fires
  • Less prone to false alarms from cooking

3. Heat Detectors

  • Respond to temperature changes, not smoke
  • Used in kitchens or garages where smoke alarms would false alarm
  • Completely incapable of detecting any gases

Combination Smoke and CO Detectors

For comprehensive protection, many homeowners choose combination units that include:

  • Both photoelectric smoke detection and CO detection
  • Distinct alarm patterns (usually 3 beeps for smoke, 4 beeps for CO)
  • Voice alerts specifying the danger type
  • Battery backup in hardwired models

Important: Even with combination units, you typically need multiple detectors placed according to both smoke and CO placement guidelines for optimal protection.

Proper Placement for Complete Protection

Detector Type Recommended Locations Installation Height
Smoke Detectors Every bedroom, outside sleeping areas, each level including basement Ceiling or high on wall (6-12" from ceiling)
CO Detectors Near sleeping areas, each habitable level, near attached garage Breathing height (about 5 feet) or per manufacturer

Maintenance Requirements

Both types of detectors require regular maintenance:

  • Monthly testing: Press test button on all detectors
  • Battery replacement: Annually or when low battery chirps
  • Unit replacement: Smoke detectors every 10 years, CO detectors every 5-7 years
  • Cleaning: Vacuum detectors every 6 months to prevent dust buildup
Prev:    Do Carbon Monoxide Detectors Detect Gas Leaks
Next:    Can a smoke detector detect small smoke
Best-Selling Products
Wireless Interconnected smoke Detector AJ-763
Wireless Interconnected smoke Detector AJ-763
RF433mhz Wireless Interconnected DC3Volt Lithium battery 10 years of battery life Big button for ...
wireless smoke and carbon monoxide combo Alarm AJ-963SCU4
wireless smoke and carbon monoxide combo Alarm AJ-963SCU4
Smoke &CO 2-in-1 wireless Interconnected 10 years of battery life 10 years of CO Sensor EN146...
AJ-938WB Wifi smoke and carbon monoxide detector
AJ-938WB Wifi smoke and carbon monoxide detector
wifi smoke and carbon monoxide detector Smart phone app control Smoke and CO 2-in-1 10 years of b...
Wifi Smoke Alarms AJ-763W
Wifi Smoke Alarms AJ-763W
TUYA smart Application 10 years of battery CE EN14604 approved Low battery warmly Check alarm hi...
AJ-963TA4 Hardwired Interconnected Heat Alarm
AJ-963TA4 Hardwired Interconnected Heat Alarm
AC220V-AC240V Main powered EN50291 approved RF433mhz Wireless interconnected Compatible with Smok...
240V Hardwired Wifi Interconnected Smoke Alarm (AS3786) AJ-960SIWA
240V Hardwired Wifi Interconnected Smoke Alarm (AS3786) AJ-960SIWA
AC220V-AC240V Mains powered, WIFI Version AS3786 Approved RF433mhz Wireless interconnected TUYA ...
AJ-960SCT stand alone 3-in -1 smoke heat and carbon monoxide combination detector
AJ-960SCT stand alone 3-in -1 smoke heat and carbon monoxide combination detector
Smoke &CO& Heat 3-in-1 10 years of battery life 10 years of CO Sensor Low battery warning...
AJ-939 ETL Smoke & Carbon Monoxide Alarms
AJ-939 ETL Smoke & Carbon Monoxide Alarms
Smoke and CO 2-in-1 10 years of battery life 10 years of Figaro CO sensor ETL UL217/UL2034 listed...
Interconnected Gas detectors AJ-981
Interconnected Gas detectors AJ-981
Designed to detect gas, LPG Gas alarm sensetivity:10%LEL WIFI/ZIGBEE/RF optional
AJ-963CA4 Hardwired Interconnected Carbon Monoxide Alarm
AJ-963CA4 Hardwired Interconnected Carbon Monoxide Alarm
AC220V-AC240V Main powered EN50291 approved RF433mhz Wireless interconnected Compatible with heat...
Latest News
What is ul 217 smoke alrams    2025-07-30
what is humidity fire alarm    2025-07-28
Anka Sci-tech logo
Anka Sci-tech Co., Limited established in 2007, is a high-tech enterprise specializing in the whole process of research, development, manufacture and marketing the Fire and home alarm products.
The main products produced by the company include smoke detectors, carbon monoxide detectors, heat detectors, etc
Contact us 
Tel:0755 89603006
Phone:13823200453
Email:anka@anka-security.com
Office:602, Floor 6, Building 15, Longbi industrial area, No. 27, Dafa Road, Bantian Street, Longgang District, Shenzhen City, 518129, P.R.China
Factory:2 fl,yangshunmei tech park,Tangkou industrial area, Xinxu town,Huiyang District, Huizhou city, Guangdong province, China.
WhatsApp Ico Gif
Email Ico Gif
Anka Sci-tech Co., Limited All Rights Reserved